1. Service Hotline

                      +86 13711845437

                      Manager Zhang

                      Introduction and parameters of metal separator

                      Author:muying Source:muying Time:2022-08-16 23:06:27 views:

                      The metal separator adopts German technology and has high sensitivity.It is used to detect metals in flake, powder and granular products.

                      Introduction to metal separator

                      The metal separator adopts German technology and has high sensitivity.It is used to detect metals in flake, powder and granular products.At least iron beads with a diameter of more than 0.3mm or slender metal wires and larger metal objects can be detected.Even if metal objects are sealed inside the product, they can be detected.The detected metal and some products are discharged through the outlet by controlling the cylinder bar through the solenoid valve.It solves the harm of metal objects in the plastic industry when processing and recycling plastics, manufacturing plastic particles and manufacturing plastic products.It avoids the scratch and blockage caused by metal to the injection molding machine and extruder.The production efficiency and the qualified rate of products are improved


                      Metal separator parameters

                        

                      Model

                      LMS25

                      LMS35

                      LMS50

                      Channel size

                      Φ25mm

                      Φ35mm

                      Φ50mm

                      Detection speed

                      200-300Kg/h

                      300-400Kg/h

                      700-800Kg/h

                      Product falling height

                      500mm

                      Suitable products

                      Granular/powdery/flake

                      Mode of use

                      Free fall

                      Separation mode

                      Automatic separation

                      Installation mode

                      Vertical installation

                      Product temperature

                      80

                      ambient temperature

                      -10~80

                      air pressure

                      3~5Bar

                      working voltage

                      AC220-240V,50/60Hz

                      texture of material

                      Low carbon steel plate

                      length,width,height

                      310*325*400mm

                      Maximum sensitivity

                      Fe≥φ0.3mm

                      304SUS≥φ0.6mm

                      Non-Fe≥φ0.4mm

                      Fe≥φ0.4mm

                      304SUS≥φ0.8mm

                      Non-Fe≥φ0.5mm

                      Fe≥φ0.5mm

                      304SUS≥φ1.0mm

                      Non-Fe≥φ0.6mm

                      *Detection speed:

                      The actual detection speed is related to the density, fluidity and speed of the product

                      *Sensitivity

                      The above is the highest sensitivity without any effect.In actual use, it will be affected by the shape and direction of metal, service environment and products.Spherical metal is usually used as the standard

                      Model

                      LMS65

                      LMS80

                      LMS100

                      Channel size

                      Φ65mm

                      Φ80mm

                      Φ100mm

                      Detection speed

                      800-1000Kg/h

                      1000-1200Kg/h

                      1200-1400Kg/h

                      Product falling height

                      500mm

                      Suitable products

                      Granular/powdery/flake

                      Mode of use

                      Free fall

                      Separation mode

                      Automatic separation

                      Installation mode

                      Vertical installation

                      Product temperature

                      50

                      ambient temperature

                      -10~50

                      air pressure

                      3~5Bar

                      working voltage

                      AC220-240V,50/60Hz

                      texture of material

                      Low carbon steel plate

                      length,width,height

                      310*325*400mm

                      410*380*500mm

                      Maximum sensitivity

                      Fe≥φ0.7mm

                      304SUS≥φ1.2mm

                      Non-Fe≥φ0.8mm

                      Fe≥φ0.9mm

                      304SUS≥φ1.5mm

                      Non-Fe≥φ1.0mm

                      Fe≥φ1.5mm

                      304SUS≥φ2.0mm

                      Non-Fe≥φ1.6mm

                      *Detection speed:

                      The actual detection speed is related to the density, fluidity and speed of the product

                      *Sensitivity

                      The above is the highest sensitivity without any effect.In actual use, it will be affected by the shape and direction of metal, service environment and products.Spherical metal is usually used as the standard